{"id":2059,"date":"2012-06-23T16:01:40","date_gmt":"2012-06-23T14:01:40","guid":{"rendered":"http:\/\/en.sma-sunny.com\/?p=2059"},"modified":"2017-12-13T15:56:36","modified_gmt":"2017-12-13T14:56:36","slug":"decentralized-battery-storage-as-a-solution","status":"publish","type":"post","link":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/","title":{"rendered":"Decentralized Battery Storage as a Solution"},"content":{"rendered":"<p>Storage systems can help increase self-consumption and relieve the power distribution grid with decentralized systems offering numerous advantages.<\/p>\n<p><!--more--><\/p>\n<p>&nbsp;<\/p>\n<p>It is hard to deny the major role that photovoltaics have played in furthering the energy revolution. In June 2011, all PV plants in Germany combined, generated enough power to meet peak demand at midday hours while maintaining an almost constant baseload.\u00a0 Despite good correlation in time and the excellent predictability of solar energy, the question arises as to how additional PV power can be added to the power distribution grid. Even today one can check daily statistics on the <a href=\"http:\/\/www.transparency.eex.com\/en\/\" target=\"_blank\">EXX transparency platform<\/a> and often see slight midday troughs and morning and evening increases in the conventional power supply.<\/p>\n<p>To avoid greater fluctuations in the conventional power supply when installing additional PV capacity, the intermediate storage of solar power is essential. Intermediate storage also reduces the distribution grid load by limiting peak power generation and consumption and helps lower system expansion needs. The range of uses for intermediate storage is nowhere near exhausted. Decentralized storage systems can increase self-sufficiency and improve supply security with a backup electricity supply while providing the technical basis for future grid services. In short, decentralized storage systems are the key to converting the electricity supply into a smart-grid based on renewables.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Advantages of decentralized energy storage<\/strong><\/p>\n<p>The fluctuating power generation capacity using renewable energy needs to be balanced on all levels, from international, national and regional power distribution grids to the household grids of private and commercial plant operators (Fig. 1). This requires the ability to not only store energy on a temporary basis, but also load management and feed-in management. In all three cases there are excellent reasons why local, decentralized applications represent the best solution: In Germany, more than 70 percent of PV power comes from smaller PV systems feeding into the low-voltage grid. As this is the same voltage level where the majority of power is consumed, a decentralized balancing of power can benefit from short distances between the power generator, load and storage system and therefore minimize transmission losses and grid load.<\/p>\n<div id=\"attachment_2072\" style=\"width: 585px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/en.sma-sunny.com\/files\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN.png\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2072\" class=\"wp-image-2072 lazyload\" title=\"Fig. 1: The future electricity supply model: Power balancing on all levels while  being as decentralized as possible.\" data-src=\"http:\/\/en.sma-sunny.com\/files\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN.png\" alt=\"Fig. 1: The future electricity supply model: Power balancing on all levels while being as decentralized as possible.\" width=\"575\" height=\"504\" data-srcset=\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN.png 1969w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN-262x230.png 262w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN-768x674.png 768w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN-1024x898.png 1024w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN-1500x1316.png 1500w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN-705x618.png 705w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN-450x395.png 450w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/EE-Leistungsausgleich-auf-allen-Ebenen-EN-1200x1053.png 1200w\" data-sizes=\"(max-width: 575px) 100vw, 575px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 575px; --smush-placeholder-aspect-ratio: 575\/504;\" \/><\/a><p id=\"caption-attachment-2072\" class=\"wp-caption-text\">Fig. 1: The future electricity supply model: Power balancing on all levels while being as decentralized as possible.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>In terms of viable battery types, there are no significant economies of scale that can make more largely dimensioned batteries cheaper and more efficient. Batteries basically consist of smaller battery cells which are just combined to achieve the desired storage capacity. Decentralized storage also offers a remarkable expansion dynamics: As the example of installed PV capacity clearly shows, significant range can be added very quickly using small, privately-financed and adequately subsidized units, since this kind of investment does not depend on business models and investors. In contrast to distribution grid operators, private homeowners have a real incentive to use storage systems. These systems not only allow greater independence from energy providers and ensure a fail-safe electricity supply, they also offer real financial incentives through an increase in self-consumption and the use of time-variable feed-in tariffs. Distribution grid operators do not have a business model for operating local power storage systems. In fact, current laws actually make it illegal for them to operate storage systems. They also have to contend with longer planning and certification periods as well as the financial constraints resulting from not having a business model.\u00a0 Therefore, there are many good reasons to focus on decentralized storage systems for domestic use.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>No increase in grid load with storage-assisted self-consumption<\/strong><\/p>\n<p>Storage systems currently on the market focus on increasing the self-consumption rate which is beneficial for two reasons: First, the self-consumption of solar power lowers the effective feed-in capacity and thus the load on the distribution grid. Second, self-consumption increases the economic yield of PV plants despite the ever rising electricity prices. In particular, when considering the proposed subsidy cuts with the feed-in compensation stipulated in the German Renewable Energy Sources Act, which is limited to 80 percent of generated kilowatt hours, self-consumption is now more critical than ever to achieving profitability. <em>(Editor&#8217;s note: According to the final EEG amendment,\u00a0a maximum of 90 percent of the annually generated kWh is compensated, effective as of January 1, 2014)\u00a0<\/em><\/p>\n<p>Smart energy management and storage systems make it possible to actually increase the rate of self-consumption by a significant degree. Yet for some time now there has been a concern that an increased self-consumption using storage systems could cause an additional burden for the power distribution grid. The line of argument: Due to the economic viability, most of the installed storage systems would have a quite small storage capacity. Therefore, under good weather conditions, they would be fully charged even before the midday hours of peak power generation. In that moment, all these PV plants would feed straight into the power distribution grid, causing a sudden power surge.<\/p>\n<p>This scenario however leaves out a few important aspects. The geographical distribution of PV plants (at different longitudes and under different weather condition) as well as different PV array alignments, PV power ratings and storage capacities help counter this simultaneous effect. Another aspect ignored involves the charging characteristics of common storage systems: With the storage systems currently available, the charging current does not suddenly drop to zero when the battery is full. Instead, a charging algorithm ensures relatively smooth control over the charging current. And unlike the solar irradiation, the charging and discharging power can be regulated at any time to prevent power spikes. Another fact that counters the fear of massive power spikes is that only a relatively small of storage power is needed to make increased self-consumption economically viable, not at least due to the power-dependent efficiency of the battery. For this reason, even a sudden interruption in the charging process would not normally cause a power spike on the level of maximum PV power. In fact, switching large household appliances on and off usually has a much greater effect.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>SMA field test confirms grid relief<\/strong><\/p>\n<p>This assessment was confirmed by a field test that SMA carried out, collecting operating data from 10 PV plants with grid-connected storage systems over a period of 12\u00a0months. Since the effect of the storage system is easy to calculate, the relevant comparison values are also provided. The result: No performance data recorded from any PV plant, on any day, indicated higher grid exchange capacity caused by the storage system. Actually the opposite was shown: Given constant maximum values, the average rates of change in the grid exchange capacity actually went down by a significant degree in all cases.\u00a0 In the system with the smallest PV peak power, the rate decreased by about 26 percent, and this despite an operational control designed for maximum self-consumption. Figure 2 and 3 show the power generation and consumption values for a four-person home with a 5.6\u00a0kWp PV power plant \u2013 both without and with a storage system included.<\/p>\n<div id=\"attachment_2073\" style=\"width: 585px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/en.sma-sunny.com\/files\/2012\/06\/Tagesgang-Grafik-27.6.2011-ohne-Speicher-EN.png\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2073\" class=\"size-full wp-image-2073 lazyload\" title=\"Fig. 2: Real power generation and consumption values of a four-person home with a 5.6 kWp PV system\" data-src=\"http:\/\/en.sma-sunny.com\/files\/2012\/06\/Tagesgang-Grafik-27.6.2011-ohne-Speicher-EN-e1340381187248.png\" alt=\"Fig. 2: Real power generation and consumption values of a four-person home with a 5.6 kWp PV system\" width=\"575\" height=\"490\" data-srcset=\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Tagesgang-Grafik-27.6.2011-ohne-Speicher-EN-e1340381187248.png 575w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Tagesgang-Grafik-27.6.2011-ohne-Speicher-EN-e1340381187248-262x223.png 262w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Tagesgang-Grafik-27.6.2011-ohne-Speicher-EN-e1340381187248-450x383.png 450w\" data-sizes=\"(max-width: 575px) 100vw, 575px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 575px; --smush-placeholder-aspect-ratio: 575\/490;\" \/><\/a><p id=\"caption-attachment-2073\" class=\"wp-caption-text\">Fig. 2: Real power generation and consumption values of a four-person home with a 5.6 kWp PV system<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>Apart from the greatly reduced grid feed-in that intermediate storage of solar power results in, it is easy to see that large fluctuations in the grid exchange capacity are caused primarily by the activation of heavy loads and not by the 2.2\u00a0kW storage system. Yet the overall grid exchange capacity decreases, which is reflected in the aforementioned annual averages.<\/p>\n<div id=\"attachment_2070\" style=\"width: 583px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/en.sma-sunny.com\/files\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Eigenverbrauch-EN.png\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2070\" class=\"size-full wp-image-2070 lazyload\" title=\"Fig. 3: The same situation with a storage system for increased self-consumption: The amount of PV energy fed to the grid drops significantly; it does not increase the load on the  power distribution grid.\" data-src=\"http:\/\/en.sma-sunny.com\/files\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Eigenverbrauch-EN-e1340381874525.png\" alt=\"Fig. 3: The same situation with a storage system for increased self-consumption: The amount of PV energy fed to the grid drops significantly; it does not increase the load on the power distribution grid.\" width=\"573\" height=\"487\" data-srcset=\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Eigenverbrauch-EN-e1340381874525.png 573w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Eigenverbrauch-EN-e1340381874525-262x223.png 262w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Eigenverbrauch-EN-e1340381874525-450x382.png 450w\" data-sizes=\"(max-width: 573px) 100vw, 573px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 573px; --smush-placeholder-aspect-ratio: 573\/487;\" \/><\/a><p id=\"caption-attachment-2070\" class=\"wp-caption-text\">Fig. 3: The same situation with a storage system for increased self-consumption: The amount of PV energy fed to the grid drops significantly; it does not increase the load on the power distribution grid.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p><strong>Additional grid relief through intelligent power storage<\/strong><\/p>\n<p>With an operational control system designed to reduce grid load, this positive effect can actually be amplified. It is conceivable, for example, to configure a storage system for \u201cpeak shaving\u201d, which means that any peak power not concurrently balanced by corresponding loads will be absorbed by the battery to maintain a specific feed-in capacity. In the opposite case, the storage system limits the amount of power drawn from the power distribution grid by providing additional power when needed. Figure 4 demonstrates this operating method based on real power generation and consumption values from the SMA field test. The battery is now charged when the feed-in capacity exceeds 1.9\u00a0kW and can therefore buffer power spikes over the entire period of power generation. Compared to conventional storage systems with an identical increase in self-consumption, this simple additional rule leads to a significant reduction in the grid exchange capacity and much smaller maximum values.<\/p>\n<div id=\"attachment_2071\" style=\"width: 585px\" class=\"wp-caption alignnone\"><a href=\"http:\/\/en.sma-sunny.com\/files\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Netzentlastung-EN.png\"><img decoding=\"async\" aria-describedby=\"caption-attachment-2071\" class=\"size-full wp-image-2071 lazyload\" title=\"Fig. 4: Option with simulated storage model for maximum grid relief: Despite the same  storage capacity and power, the maximum value and grid exchange capacity decrease. \" data-src=\"http:\/\/en.sma-sunny.com\/files\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Netzentlastung-EN-e1340381985891.png\" alt=\"Fig. 4: Option with simulated storage model for maximum grid relief: Despite the same storage capacity and power, the maximum value and grid exchange capacity decrease.\" width=\"575\" height=\"489\" data-srcset=\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Netzentlastung-EN-e1340381985891.png 575w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Netzentlastung-EN-e1340381985891-262x223.png 262w, https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Tagesgang-Grafik-27.6.2011-mit-Speicher-Netzentlastung-EN-e1340381985891-450x383.png 450w\" data-sizes=\"(max-width: 575px) 100vw, 575px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 575px; --smush-placeholder-aspect-ratio: 575\/489;\" \/><\/a><p id=\"caption-attachment-2071\" class=\"wp-caption-text\">Fig. 4: Option with simulated storage model for maximum grid relief: Despite the same storage capacity and power, the maximum value and grid exchange capacity decrease.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>The graphic clearly shows the enormous potential that decentralized smart storage systems have for relieving the power distribution grid. To realize that potential, however, a reliable forecast of PV power generation is necessary to ensure that the battery can fully charge even under irregular irradiation conditions. Of almost equal importance is information on the expected home load profile and an accurate measurement of power consumption, as any consumption that occurs while PV power is being generated reduces the grid exchange capacity and hence the need for storage. The ability to measure power at small time intervals is critical for regulating fast pulsing loads such as electric stoves.<\/p>\n<p>The ideal solution is therefore a storage system that is part of a decentralized, smart energy management system such as the new Sunny Home Manager from SMA. This device is not only able to estimate power generation and loads, but also can record all relevant energy flows in a home via three S0- and D0-meter interfaces. Furthermore it is able to automatically control the operating times of individual loads in order to optimize the self-consumption rate. Based on the above energy management system, decentralized storage systems can significantly reduce grid load while increasing self-consumption, self-sufficiency and security of supply.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p align=\"left\"><span style=\"color: #808080;\"><em><strong>Explanation of diagrams<\/strong><\/em><\/span><\/p>\n<ul>\n<li><span style=\"color: #808080;\"><em>Energy consumption at home equals the sum of all gray, green and orange areas (purchased electricity + direct self-consumption + energy drawn from the battery).<\/em><\/span><\/li>\n<li><span style=\"color: #808080;\"><em>The gray areas also correspond to the areas bordering positive grid exchange capacity.<\/em><\/span><\/li>\n<li><span style=\"color: #808080;\"><em>The blue areas correspond to the energy fed to the power distribution grid as well as the area bordering the negative <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> grid exchange capacity.<\/em><\/span><\/li>\n<li><span style=\"color: #808080;\"><em>The yellow and orange areas correspond to the amount of energy stored in and discharged from the battery.<\/em><\/span><\/li>\n<\/ul>\n<p><span style=\"color: #808080;\"><em><strong><br \/>\nReading example for Fig. 4:<\/strong><\/em><\/span><\/p>\n<p align=\"left\"><span style=\"color: #808080;\"><em>Between 9\u00a0a.m. and 10\u00a0a.m. there is about 3\u00a0kW of power generation capacity but only about 700\u00a0W of self-consumption <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> capacity. This widening difference in capacity is absorbed by the storage system (yellow area) to make sure that grid feed-in <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> (red curve) does not exceed the 1.9\u00a0kW limiting value.<\/em><\/span><\/p>\n<p align=\"left\"><span style=\"color: #808080;\"><em>After 10\u00a0a.m. demand exceeds PV power generation, which, as a result, is entirely self-consumed (green area). Any additional <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> power that is needed is not drawn from the power distribution grid but instead from the storage system (orange area), which <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> means the grid exchange capacity remains zero.<\/em><\/span><\/p>\n<p align=\"left\"><span style=\"color: #808080;\"><em>Only between 11:30\u00a0a.m and 2\u00a0p.m will the feed-in capacity exceed the 1.9\u00a0kW threshold since the maximum power of the <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> 2.2\u00a0kW storage system is unable to bridge the difference between power generation and consumption. After 2\u00a0p.m power <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> consumption continues to increase steadily and as a result the feed-in capacity remains below 1.9\u00a0kW, even without power <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> storage.<\/em><\/span><\/p>\n<p align=\"left\"><span style=\"color: #808080;\"><em>At around 8\u00a0a.m. and 5\u00a0p.m. power consumption exceeds the sum of self-consumption and maximum storage capacity, <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> which is the reason for the &#8220;gray peaks&#8221; at those times. The remaining power needed is therefore drawn from the power <\/em><\/span><br \/>\n<span style=\"color: #808080;\"> <em> distribution grid, which is also shown by the spikes in grid exchange capacity.<\/em><\/span><\/p>\n\n\n<div class=\"kk-star-ratings kksr-auto kksr-align-left kksr-valign-bottom\"\n    data-payload='{&quot;align&quot;:&quot;left&quot;,&quot;id&quot;:&quot;2059&quot;,&quot;slug&quot;:&quot;default&quot;,&quot;valign&quot;:&quot;bottom&quot;,&quot;ignore&quot;:&quot;&quot;,&quot;reference&quot;:&quot;auto&quot;,&quot;class&quot;:&quot;&quot;,&quot;count&quot;:&quot;0&quot;,&quot;legendonly&quot;:&quot;&quot;,&quot;readonly&quot;:&quot;&quot;,&quot;score&quot;:&quot;0&quot;,&quot;starsonly&quot;:&quot;&quot;,&quot;best&quot;:&quot;5&quot;,&quot;gap&quot;:&quot;1&quot;,&quot;greet&quot;:&quot;&quot;,&quot;legend&quot;:&quot;0\\\/5 - (0 votes)&quot;,&quot;size&quot;:&quot;22&quot;,&quot;title&quot;:&quot;Decentralized Battery Storage as a Solution&quot;,&quot;width&quot;:&quot;0&quot;,&quot;_legend&quot;:&quot;{score}\\\/{best} - ({count} {votes})&quot;,&quot;font_factor&quot;:&quot;1.25&quot;}'>\n            \n<div class=\"kksr-stars\">\n    \n<div class=\"kksr-stars-inactive\">\n            <div class=\"kksr-star\" data-star=\"1\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" data-star=\"2\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" data-star=\"3\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" data-star=\"4\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" data-star=\"5\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n    <\/div>\n    \n<div class=\"kksr-stars-active\" style=\"width: 0px;\">\n            <div class=\"kksr-star\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n            <div class=\"kksr-star\" style=\"padding-right: 1px\">\n            \n\n<div class=\"kksr-icon\" style=\"width: 22px; height: 22px;\"><\/div>\n        <\/div>\n    <\/div>\n<\/div>\n                \n\n<div class=\"kksr-legend\" style=\"font-size: 17.6px;\">\n            <span class=\"kksr-muted\"><\/span>\n    <\/div>\n    <\/div>\n<div class='printomatic pom-default ' id='id6546'  data-print_target='article'><\/div>","protected":false},"excerpt":{"rendered":"<p>Storage systems can help increase self-consumption and relieve the power distribution grid with decentralized systems offering numerous advantages.<\/p>\n","protected":false},"author":8,"featured_media":2074,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[46,58],"tags":[662,573,663,664,105,147,575,665],"class_list":["post-2059","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-solutions","tag-decentralized-energy-storage","tag-energy-management","tag-energy-transition-2","tag-grid-relief","tag-mps","tag-pv","tag-self-consumption","tag-sunny-backup-system"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v23.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Decentralized Battery Storage as a Solution - Sunny. SMA Corporate Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Decentralized Battery Storage as a Solution - Sunny. SMA Corporate Blog\" \/>\n<meta property=\"og:description\" content=\"Storage systems can help increase self-consumption and relieve the power distribution grid with decentralized systems offering numerous advantages.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/\" \/>\n<meta property=\"og:site_name\" content=\"Sunny. SMA Corporate Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/facebook.com\/SMASolarTechnology\" \/>\n<meta property=\"article:published_time\" content=\"2012-06-23T14:01:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-12-13T14:56:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Titelbild-Speicherartikel-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"572\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Felix Kever\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@SMAsolar\" \/>\n<meta name=\"twitter:site\" content=\"@SMAsolar\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Felix Kever\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/\",\"url\":\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/\",\"name\":\"Decentralized Battery Storage as a Solution - Sunny. SMA Corporate Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.sma-sunny.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Titelbild-Speicherartikel-1.jpg\",\"datePublished\":\"2012-06-23T14:01:40+00:00\",\"dateModified\":\"2017-12-13T14:56:36+00:00\",\"author\":{\"@id\":\"https:\/\/www.sma-sunny.com\/en\/#\/schema\/person\/181f0a62b451c856c5f3e0b3282570df\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#primaryimage\",\"url\":\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Titelbild-Speicherartikel-1.jpg\",\"contentUrl\":\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Titelbild-Speicherartikel-1.jpg\",\"width\":572,\"height\":300,\"caption\":\"Decentralized Battery Storage as a Solution\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.sma-sunny.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Decentralized Battery Storage as a Solution\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sma-sunny.com\/en\/#website\",\"url\":\"https:\/\/www.sma-sunny.com\/en\/\",\"name\":\"Sunny. SMA Corporate Blog\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sma-sunny.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.sma-sunny.com\/en\/#\/schema\/person\/181f0a62b451c856c5f3e0b3282570df\",\"name\":\"Felix Kever\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.sma-sunny.com\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2018\/02\/felix_kever.jpg\",\"contentUrl\":\"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2018\/02\/felix_kever.jpg\",\"caption\":\"Felix Kever\"},\"url\":\"https:\/\/www.sma-sunny.com\/en\/author\/felix\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Decentralized Battery Storage as a Solution - Sunny. SMA Corporate Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/","og_locale":"en_GB","og_type":"article","og_title":"Decentralized Battery Storage as a Solution - Sunny. SMA Corporate Blog","og_description":"Storage systems can help increase self-consumption and relieve the power distribution grid with decentralized systems offering numerous advantages.","og_url":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/","og_site_name":"Sunny. SMA Corporate Blog","article_publisher":"https:\/\/facebook.com\/SMASolarTechnology","article_published_time":"2012-06-23T14:01:40+00:00","article_modified_time":"2017-12-13T14:56:36+00:00","og_image":[{"width":572,"height":300,"url":"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Titelbild-Speicherartikel-1.jpg","type":"image\/jpeg"}],"author":"Felix Kever","twitter_card":"summary_large_image","twitter_creator":"@SMAsolar","twitter_site":"@SMAsolar","twitter_misc":{"Written by":"Felix Kever","Estimated reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/","url":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/","name":"Decentralized Battery Storage as a Solution - Sunny. SMA Corporate Blog","isPartOf":{"@id":"https:\/\/www.sma-sunny.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#primaryimage"},"image":{"@id":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Titelbild-Speicherartikel-1.jpg","datePublished":"2012-06-23T14:01:40+00:00","dateModified":"2017-12-13T14:56:36+00:00","author":{"@id":"https:\/\/www.sma-sunny.com\/en\/#\/schema\/person\/181f0a62b451c856c5f3e0b3282570df"},"breadcrumb":{"@id":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#primaryimage","url":"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Titelbild-Speicherartikel-1.jpg","contentUrl":"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2012\/06\/Titelbild-Speicherartikel-1.jpg","width":572,"height":300,"caption":"Decentralized Battery Storage as a Solution"},{"@type":"BreadcrumbList","@id":"https:\/\/www.sma-sunny.com\/en\/decentralized-battery-storage-as-a-solution\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.sma-sunny.com\/en\/"},{"@type":"ListItem","position":2,"name":"Decentralized Battery Storage as a Solution"}]},{"@type":"WebSite","@id":"https:\/\/www.sma-sunny.com\/en\/#website","url":"https:\/\/www.sma-sunny.com\/en\/","name":"Sunny. SMA Corporate Blog","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sma-sunny.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.sma-sunny.com\/en\/#\/schema\/person\/181f0a62b451c856c5f3e0b3282570df","name":"Felix Kever","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.sma-sunny.com\/en\/#\/schema\/person\/image\/","url":"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2018\/02\/felix_kever.jpg","contentUrl":"https:\/\/www.sma-sunny.com\/wp-content\/uploads\/2018\/02\/felix_kever.jpg","caption":"Felix Kever"},"url":"https:\/\/www.sma-sunny.com\/en\/author\/felix\/"}]}},"_links":{"self":[{"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/posts\/2059","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/comments?post=2059"}],"version-history":[{"count":0,"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/posts\/2059\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/media\/2074"}],"wp:attachment":[{"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/media?parent=2059"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/categories?post=2059"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.sma-sunny.com\/en\/wp-json\/wp\/v2\/tags?post=2059"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}